Panel type DO analyzer in a compact DIN 96 size One-touch calibration and various self-diagnostic functions 2-point contacts signal, 4 - 20mA output (RS-232 optional)  Power supply: 90 - 264VAC, 50/60Hz Meas. range Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L

Immersion/Drop-In Type DO Holder OC-711 / OC-950 Lightweight PVC holder; length of immersion type holder: 0.3 - 3.5 m, length of stainless steel protection pipe for drop-in type holder: 2 - 6 m Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)

Detector with Water Jet Cleaner JOC-711C / JOC-950C Cleaning electrode contamination by jetting water or air onto the electrode Immersion type (JOC-711C) and drop-in type (JOC-950C) Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)

Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire) Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case Simplified calibration procedure; auto detection of electrode deterioration Alterable output range Automated self-diagnosis of fault (burn-out output) Meas. range Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L

Low-Concentration DO Transmitter OBM-300 (4-wire) Multi-functional low-concentration DO analyzer for field installation in a compact diecast aluminum case 3 ranges (automatically switched), 2-point regulated output Alterable output range One-touch calibration and various self-diagnostic functions Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 999.9 μg/L

Panel Type Low-Concentration DO Transmitter OBM-100H Panel type low-concentration DO analyzer in a compact DIN 96 size 2-point regulated, 4 - 20mA, RS-232 output One-touch calibration and various self-diagnostic functions Power supply: 90~264VAC, 50/60Hz Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 1000 μg/L

Low-Concentration DO Detector for Pure Water OC-64 Suitable for low-concentration DO measurement (pure water in semiconductor factories, boiler water in power plants) Micro-flow (100mL/min) with special flow cell Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode) Lead wire: ELW-32

Created on: 21 January 2014

Polarograph type DO analyzer with intrinsically safe explosion-proof function (combined with a Zener Barrier) Alterable output range Types of detectors available: immersion, flow-through and fermentation-used (electrodes: ELD-017/ELD-019) Meas. range Minimum : 0 - 1 mg/L Maximum: 0 - 20 mg/L